• About
  • Masthead
  • License Content
  • Advertise
  • Submit Press Release
  • RSS/Email List
  • 2MM Podcast
  • Write for us
  • Contact Us
2 Minute Medicine
No Result
View All Result

No products in the cart.

SUBSCRIBE
  • Specialties
    • All Specialties, All Recent Reports
    • Cardiology
    • Chronic Disease
    • Dermatology
    • Emergency
    • Endocrinology
    • Gastroenterology
    • Imaging and Intervention
    • Infectious Disease
    • Nephrology
    • Neurology
    • Obstetrics
    • Oncology
    • Ophthalmology
    • Pediatrics
    • Pharma
    • Preclinical
    • Psychiatry
    • Public Health
    • Pulmonology
    • Rheumatology
    • Surgery
  • The Scan+
  • Wellness
  • Classics™+
    • 2MM+ Online Access
    • Paperback and Ebook
  • Rewinds
  • Visual
  • Career
  • Podcasts
  • Partners
    • License Content
    • Submit Press Release
    • Advertise with Us
  • Account
    • Subscribe
    • Sign-in
    • My account
2 Minute Medicine
  • Specialties
    • All Specialties, All Recent Reports
    • Cardiology
    • Chronic Disease
    • Dermatology
    • Emergency
    • Endocrinology
    • Gastroenterology
    • Imaging and Intervention
    • Infectious Disease
    • Nephrology
    • Neurology
    • Obstetrics
    • Oncology
    • Ophthalmology
    • Pediatrics
    • Pharma
    • Preclinical
    • Psychiatry
    • Public Health
    • Pulmonology
    • Rheumatology
    • Surgery
  • The Scan+
  • Wellness
  • Classics™+
    • 2MM+ Online Access
    • Paperback and Ebook
  • Rewinds
  • Visual
  • Career
  • Podcasts
  • Partners
    • License Content
    • Submit Press Release
    • Advertise with Us
  • Account
    • Subscribe
    • Sign-in
    • My account
SUBSCRIBE
2 Minute Medicine
Subscribe
Home StudyGraphics

#VisualAbstract: Oxygenated hypothermic perfusion reduces post-kidney transplant complications

byConstance Wu
December 16, 2020
in StudyGraphics
Reading Time: 3 mins read
0
Share on FacebookShare on Twitter

1. Oxygenated hypothermic machine perfusion (HMPO2) of kidneys donated after circulatory death was associated with fewer severe complications and lower rates of graft failure compared to hypothermic machine perfusion without oxygenation (HMP).

2. There was no significant difference in mean eGFR between HMPO2 and HMP despite potential beneficial effects suggested by analysis of secondary outcomes.

Evidence Rating Level: 1 (Excellent)

Study Rundown: Kidney transplant is the preferred treatment for end-stage renal disease and significantly improves quality of life and survival compared to dialysis. Hypothermic preservation is a cornerstone in reducing ischemic-reperfusion injury and is accomplished clinically through either static cold storage or hypothermic machine perfusion (HMP). However, despite oxygenated HMP (HMPO2) showing promise in animal models, there were no well-designed studies assessing the effect of HMPO2 in kidney transplantation in humans. This randomized, double-blind, paired phase 3 trial comparing HMP with or without oxygenation in kidney transplantations included 106 kidney pairs from donors aged 50 or older after circulatory death. Kidney pairs were transplanted into different recipients with one kidney assigned to HMPO2 and the other to HMP without oxygenation. Results suggested that HMPO2 was safe in kidneys donated after circulatory death and mean estimated glomerular filtration rate (eGFR) was similar at 12 months post-transplant between the HMPO2 and the HMP group. However, significantly fewer severe complications (grade IIIb or greater) and lower graft failure rates were observed with HMPO2 compared with HMP. Notable limitations of the current study include the inability to identify the effect of HMPO2 on acute rejection due to not collecting the necessary data. Additionally, the choice to report eGFR only in pairs of donated kidneys with both kidneys functioning at the 12-month endpoint resulted in the exclusion of informative dropouts which may have been associated with the intervention. Nonetheless, this landmark study is the first to identify that HMPO2 may confer a clinical benefit and has the potential markedly impact clinical practice.

Click to read the study in The Lancet

Relevant Reading: Hypothermic Oxygenated New Machine Perfusion System in Liver and Kidney Transplantation of Extended Criteria Donors: First Italian Clinical Trial

RELATED REPORTS

Recognition of kidney allograft microvascular inflammation refines risk stratification for allograft outcomes

#VisualAbstract: Empagliflozin Has Cardiorenal Benefits for Chronic Kindey Disease

Prevalence of common chronic conditions in Medicare Advantage and traditional Medicare beneficiaries

In-Depth [randomized controlled trial]: This randomized, double-blind, paired, phase 3 trial was conducted at 19 transplant centers across Europe and included kidney pairs procured by controlled donation after circulatory death from donors aged ≥ 50 years. A computer-generated randomization scheme was utilized to randomly assign one kidney from each donor pair to HMPO2 and the other to standard HMP without oxygenation. The primary endpoint was estimated eGFR as a marker of renal function at 12 months post kidney transplantation. Between March 15, 2015, and April 11, 2017, a total of 197 kidney pairs were randomized with 106 available for sensitivity and secondary analysis and 83 kidney pairs available for primary outcome analysis.

At 12 months post-transplant, there was no significant difference in mean eGFR in the HMPO2 group (50.5 mL/min per 1.73m2; standard deviation [SD] 19.3) compared to the HMP group (46.7 mL/min per 1.73m2; SD 17.1) with a mean difference of 3.7 mL/min per 1.73m2 (95% CI -1.0 to 8.4; p=0.12). Graft failure at 12-months post-transplant was significantly lower in the HMPO2 group (three (3%) of 106) compared to the HMP group (11 (10%) of 106, hazard ratio (HR) 0.27, 95% CI 0.07 to 0.95; p=0.028). There was no significant difference in patient survival between the HMPO2 group and HMP group (7% vs 8%, HR 0.88, 95% CI 0.32 to 2.41; p=0.80). Fewer severe complications (Clavien-Dindo grade ≥IIIb) were reported in the HMPO2 group versus the HMP group (11%, 95% CI 8% to 14% vs 16%, 95% CI 13% to 20%; p=0.032).

Image: PD

©2020 2 Minute Medicine, Inc. All rights reserved. No works may be reproduced without expressed written consent from 2 Minute Medicine, Inc. Inquire about licensing here. No article should be construed as medical advice and is not intended as such by the authors or by 2 Minute Medicine, Inc.

 

Tags: chronic kidney disease (CKD)eGFRHMPHMPO2hypothermic machine perfusionkidney transplantOxygenated hypothermic machine perfusion (HMPO2)transplant
Previous Post

#VisualAbstract: Pembrolizumab plus chemotherapy improves survival in patients with metastatic triple-negative breast cancer

Next Post

Association between low density lipoprotein and all cause and cause specific mortality in Denmark

RelatedReports

Tenofovir disoprovil fumarate HIV prophylaxis linked with minimal kidney impact
Chronic Disease

Recognition of kidney allograft microvascular inflammation refines risk stratification for allograft outcomes

March 12, 2025
#VisualAbstract: Empagliflozin Has Cardiorenal Benefits for Chronic Kindey Disease
StudyGraphics

#VisualAbstract: Empagliflozin Has Cardiorenal Benefits for Chronic Kindey Disease

March 6, 2025
Chronic Disease

Prevalence of common chronic conditions in Medicare Advantage and traditional Medicare beneficiaries

February 25, 2025
Adaptive interim PET-CT guides treatment for advanced Hodgkin’s lymphoma
Oncology

High incidence of post-transplant lymphoproliferative disorder in Epstein-Barr virus-seronegative kidney recipients

January 27, 2025
Next Post
Thrombophilia-associated stillbirth risk appears limited to factor V Leiden

Association between low density lipoprotein and all cause and cause specific mortality in Denmark

#VisualAbstract: Trends in positive BRCA results among older women between 2008 to 2018

#VisualAbstract: Trends in positive BRCA results among older women between 2008 to 2018

30-Day mortality decreased in UK pediatric cardiac surgery from 2000-2010

Ticagrelor non-superior to clopidogrel in the reduction of PCI-related myocardial necrosis

2 Minute Medicine® is an award winning, physician-run, expert medical media company. Our content is curated, written and edited by practicing health professionals who have clinical and scientific expertise in their field of reporting. Our editorial management team is comprised of highly-trained MD physicians. Join numerous brands, companies, and hospitals who trust our licensed content.

Recent Reports

  • Measuring metabolic energy expenditure for individuals with lower limb amputation
  • App-based physical activity intervention may have a limited role among women with prior hypertensive pregnancy disorder
  • Imlunestrant extends progression-free survival in ER-positive, HER2-negative breast cancer
License Content
Terms of Use | Disclaimer
Cookie Policy
Privacy Statement (EU)
Disclaimer

© 2021 2 Minute Medicine, Inc. - Physician-written medical news.

  • Specialties
    • All Specialties, All Recent Reports
    • Cardiology
    • Chronic Disease
    • Dermatology
    • Emergency
    • Endocrinology
    • Gastroenterology
    • Imaging and Intervention
    • Infectious Disease
    • Nephrology
    • Neurology
    • Obstetrics
    • Oncology
    • Ophthalmology
    • Pediatrics
    • Pharma
    • Preclinical
    • Psychiatry
    • Public Health
    • Pulmonology
    • Rheumatology
    • Surgery
  • The Scan
  • Wellness
  • Classics™
    • 2MM+ Online Access
    • Paperback and Ebook
  • Rewinds
  • Visual
  • Career
  • Podcasts
  • Partners
    • License Content
    • Submit Press Release
    • Advertise with Us
  • Account
    • Subscribe
    • Sign-in
    • My account
No Result
View All Result

© 2021 2 Minute Medicine, Inc. - Physician-written medical news.